{"id":2944,"date":"2019-02-15T13:54:02","date_gmt":"2019-02-15T06:54:02","guid":{"rendered":"http:\/\/siampollutek.co.th\/2018\/?post_type=product&#038;p=2944"},"modified":"2019-02-15T14:16:02","modified_gmt":"2019-02-15T07:16:02","slug":"laboretory-instrumention-t9100-9200-series","status":"publish","type":"product","link":"https:\/\/siampollutek.co.th\/2018\/product\/laboretory-instrumention-t9100-9200-series\/","title":{"rendered":"T-9100\/9200 Series"},"content":{"rendered":"<p><strong>Main Features<\/strong><\/p>\n<ol>\n<li>Appearance and internal structureModern and elegant appearance, extendable design, separate structure design for optical and circuit system can efficiently avoid the loss of photometric energy.<\/li>\n<li>Convenient and intuitive operation interfaceThis series has 7-inch high resolution colored capacitive touch screen and newly developed UV-SUPER2.0 software with strong functions, which make the operation simple and easy.<\/li>\n<li>Excellent performance and stabilityTotally enclosed monochromator and optical mirror coated with SiO2 guarantee the optical components are not influenced by gas and environment.\n<p>\u25c7Philips and Hamamatsu lamps<\/p>\n<p>\u25c7Newly improved screw pole drive structure makes good wavelength repeatability and high wavelength accuracy.<\/p>\n<p>\u25c7Totally new design, superior materials and rigorous production process.<\/li>\n<li>Advanced photoelectric test system\u25c732 bit ARM11 microcontroller with clock speed up to 533MHz\n<p>\u25c720 bit analog digital device specialized for photoelectric data collection and processing from BB company.<\/p>\n<p>\u25c7Support internal huge data storage(32M), mouse operation and big SD card memory.<\/li>\n<li>\u00a0Simple and convenient maintenance\u25c7Socket type lamps make the optical adjustment not necessary and maintenance much easier.\n<p>\u25c7Separated Optical and circuit system has no cross influence and make the instrument more reliable.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p><strong>UI Design<\/strong><\/p>\n<p>1. Photometry<\/p>\n<p>Absorbency and transmittance test.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-2945\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/1-300x176.jpg\" alt=\"\" width=\"716\" height=\"420\" srcset=\"https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/1-300x176.jpg 300w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/1-600x352.jpg 600w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/1-768x450.jpg 768w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/1.jpg 1024w\" sizes=\"(max-width: 716px) 100vw, 716px\" \/><\/p>\n<p>2. Quantitative test.<\/p>\n<p>To test sample solution concentration, you can choose different methods like coefficient, standard curve, linearity, linear zero crossing and quadratic. Operators can choose single, double and tri-wavelength and change the coefficients of double and tri-wavelength. Advanced arithmetic makes curvilinear regression more precise and test data more accurate.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-2946\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/2-300x176.jpg\" alt=\"\" width=\"716\" height=\"420\" srcset=\"https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/2-300x176.jpg 300w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/2-600x352.jpg 600w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/2-768x450.jpg 768w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/2.jpg 1024w\" sizes=\"(max-width: 716px) 100vw, 716px\" \/><\/p>\n<p>3. Kinetics Measurement (Time Scanning)<\/p>\n<p>To test the sample chemical reaction process by fixed time scanning the sample solution with fixed wavelength. The equipment can calculate its changing rate after entering the corresponding parameters.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-2947\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/3-300x176.jpg\" alt=\"\" width=\"714\" height=\"419\" srcset=\"https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/3-300x176.jpg 300w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/3-600x352.jpg 600w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/3-768x450.jpg 768w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/3.jpg 1024w\" sizes=\"(max-width: 714px) 100vw, 714px\" \/><\/p>\n<p>4. Wavelength Scanning (Qualitative Test)<\/p>\n<p>To test sample solution absorbency peak, can scan the sample characteristic curve of any wavelength range between 190 and 1100nm. And do the chart overlay and arithmetic.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2948\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/4-300x176.jpg\" alt=\"\" width=\"711\" height=\"417\" \/><\/p>\n<p>5. Multi wavelength testing<\/p>\n<p>It is much more convenient for users to test the absorbency or do the arithmetic in case of several wavelengths for the same sample solution, which is much simpler than single wavelength testing.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2949\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/5-300x176.jpg\" alt=\"\" width=\"714\" height=\"419\" srcset=\"https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/5-300x176.jpg 300w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/5-600x352.jpg 600w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/5-768x450.jpg 768w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/5.jpg 1024w\" sizes=\"(max-width: 714px) 100vw, 714px\" \/><\/p>\n<p>6. DNA\/Protein Measurement<\/p>\n<p>It is a special function for specific users to make the operation easier.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2952\" src=\"http:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/6-3-300x171.png\" alt=\"\" width=\"709\" height=\"404\" srcset=\"https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/6-3-300x171.png 300w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/6-3-600x342.png 600w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/6-3-768x438.png 768w, https:\/\/siampollutek.co.th\/2018\/wp-content\/uploads\/2019\/02\/6-3.png 989w\" sizes=\"(max-width: 709px) 100vw, 709px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<table border=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td valign=\"center\" width=\"100\">Model<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">T-9100<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">T-9200<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">T-9200S<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">T-9200A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Display<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"top\" width=\"659\">7 inch TFT colored capacitive touch screen<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Wavelength Range<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">190\u00a0&#8211;\u00a01100nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Optical System<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">Single Beam<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"center\" width=\"494\">Double Beam<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Spectral Bandwidth<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">2nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">2nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">1nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">0.5,1,2,4,5nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Wavelength Accuracy<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.5nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.5nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.3nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.3nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Wavelength Repeatability<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u22640.2nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u22640.2nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u22640.1nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u22640.1nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Photometric Accuracy<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">0.2%T(0-100%T), \u00b10.002A(0-0.5A), \u00b10.004A(0.5-1A)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Photometric Repeatability<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">\u22640.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Scanning Speed<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">High, Medium and Low<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Stray Light<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"top\" width=\"659\">\u22640.05%T@220nm,360nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Baseline Flatness<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.003A<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.002A<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.001A<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">\u00b10.001A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Drift<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">0.003A\/30min@500nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">0.002A\/30min@500nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">0.001A\/30min@500nm<\/td>\n<td align=\"left\" valign=\"center\" width=\"164\">0.001A\/30min@500nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Noise<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">0.0005A@500nm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Working Mode<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">T,A,C,E<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Wavelength Setting<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">Automatic<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"100\">Detector<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">Solid Silicon Photodiode<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Light Source<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">Tungsten Halogen\/Deuterium Lamp<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Output Port<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">USB HOST, USB DRIVE, RS232, SD Card<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Power Requirements<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">AC 110-220V 50-60Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Humidity Range<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">Less Than 85%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"100\">Shipping Dimensions and Weight<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"center\" width=\"659\">770*630*340mm, 27kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Excellent optical system, high level mechanical system, advanced circuit control system, rigorous production process, friendly and intuitive software interface, good technical specifications, stable and reliable performance can meet the analysis requirements from high level and professional customers<\/p>\n","protected":false},"featured_media":2953,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_cat":[594,595],"product_tag":[],"_links":{"self":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product\/2944"}],"collection":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media\/2953"}],"wp:attachment":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media?parent=2944"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_cat?post=2944"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_tag?post=2944"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}