{"id":2328,"date":"2018-09-22T08:50:32","date_gmt":"2018-09-22T01:50:32","guid":{"rendered":"http:\/\/siampollutek.co.th\/2018\/?post_type=product&#038;p=2328"},"modified":"2018-09-22T09:18:19","modified_gmt":"2018-09-22T02:18:19","slug":"f-3500-series-insertion-electromagnetic-flow-meter","status":"publish","type":"product","link":"https:\/\/siampollutek.co.th\/2018\/product\/f-3500-series-insertion-electromagnetic-flow-meter\/","title":{"rendered":"F-3500 Series Insertion Electromagnetic Flow Meter"},"content":{"rendered":"<h4><span style=\"font-size: 15px;\">GENERAL SPECIFICATIONS<\/span><\/h4>\n<div><strong><span style=\"font-size: 15px;\">ACCURACY<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">\u00b1 1.0% of reading from 2 &#8211; 20 ft\/s<\/span><\/div>\n<div><span style=\"font-size: 15px;\">\u00b1 0.02 ft\/s below 2 ft\/s<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">FLOW RANGE<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">0.1 ft\/s to 20 ft\/s (200:1 turndown)<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">SENSING METHOD<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">Electromagnetic sensing (no moving parts)<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">PIPE SIZE RANGE<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">Standard Configuration: 3 &#8211; 72\u201d nominal diameter<\/span><\/div>\n<div><span style=\"font-size: 15px;\">Small Pipe Configuration: 1\u00bc &#8211; <\/span><span style=\"font-size: 15px;\">2\u00bd<\/span><span style=\"font-size: 15px;\">\u201d nominal diameter<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">INPUT POWER<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">20 &#8211; 28 VDC, 250 mA at 24 VDC<\/span><\/div>\n<div><span style=\"font-size: 15px;\">20 &#8211; 28 VAC, 60 Hz, 6 VA<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">LIQUID TEMPERATURE RANGE<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">15\u00b0 to 250\u00b0 F<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">AMBIENT TEMPERATURE RANGE<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">-20\u00b0 to 150\u00b0 F<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">OPERATING PRESSURE<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">400 psi maximum<\/span><\/div>\n<div><strong><span style=\"font-size: 15px;\">PRESSURE DROP<\/span><\/strong><\/div>\n<div><span style=\"font-size: 15px;\">Standard Configuration: 0.1 psi at 12 ft\/s in 3\u201d pipe, <\/span><span style=\"font-size: 15px;\">decreasing as line size increases<\/span><\/div>\n<div><span style=\"font-size: 15px;\">Small Pipe Configuration: 0.33 psi at 8 ft\/s in 1.25\u201d pipe, <\/span><span style=\"font-size: 15px;\">decreasing as the line size increases<\/span><\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"description\">\n<p>\u00a0\u00a0\u00a0\u00a0\u00a0 <span style=\"font-size: 15px;\">The F-3500 Insertion Electromagnetic Flow Meter is suitable for use in pipes ranging in size from 1\u00bc&#8221; to 72&#8243; in diameter. It features ONICON&#8217;s unique hot tap design that allows for easy insertion or removal from the pipe without the use of special tools and without disrupting flow. The low maintenance design is provided ready-to-use without the need for field programming.<\/span><\/p>\n<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0 The FB-3500 Electromagnetic Flow Meter is available for bi-directional flow applications. It provides an analog output for flow rate, a contact closure output to indicate flow direction and separate pulse outputs to totalize forward and reverse flow.<\/span><\/p>\n<p class=\"Default\"><strong>Applications<\/strong><\/p>\n<ul>\n<li><span style=\"font-size: 15px;\">Primary\/secondary decoupling loop<\/span><\/li>\n<li><span style=\"font-size: 15px;\">HVAC thermal storage tank<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Domestic water charge\/discharge<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Bi-directional process flow<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Chilled water, hot water, condenser water\u00a0&amp; water\/glycol\/brine solutions used in HVAC<\/span><\/li>\n<li><span style=\"font-size: 15px;\"><span class=\"listdescription\">M<\/span>unicipal water<\/span><\/li>\n<\/ul>\n<\/div>\n","protected":false},"featured_media":2320,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_cat":[105,103,315],"product_tag":[543,541,540,326,542],"_links":{"self":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product\/2328"}],"collection":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media\/2320"}],"wp:attachment":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media?parent=2328"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_cat?post=2328"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_tag?post=2328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}