{"id":2263,"date":"2018-09-20T11:44:17","date_gmt":"2018-09-20T04:44:17","guid":{"rendered":"http:\/\/siampollutek.co.th\/2018\/?post_type=product&#038;p=2263"},"modified":"2018-09-20T11:45:51","modified_gmt":"2018-09-20T04:45:51","slug":"fluorisense-fluoride-monitors","status":"publish","type":"product","link":"https:\/\/siampollutek.co.th\/2018\/product\/fluorisense-fluoride-monitors\/","title":{"rendered":"FluoriSense &#8211; fluoride monitors"},"content":{"rendered":"<h4><span style=\"font-size: 15px;\">Specification<\/span><\/h4>\n<p><span style=\"font-size: 15px;\">FluoriSense<\/span><br \/>\n<span style=\"font-size: 15px;\">Type :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ISE (Ion Specific Electrode) <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Reference Type :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Solid polymer junction<\/span><\/p>\n<p><span style=\"font-size: 15px;\">Measurand :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Fluoride<\/span><\/p>\n<p><span style=\"font-size: 15px;\">Slope :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0 \u00ad\u00a0\u00a0\u00a0 56 \u00b1 4mV at 25\u00b0C <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Concentration Range :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1&#215;10\u00ad6 M to saturation (0.02 ppm \u00ad saturation) <\/span><\/p>\n<p><span style=\"font-size: 15px;\">pH Range :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 5 to 7 pH at 1 x 10\u00ad6 M 5 to 11 pH at saturation <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Temperature Range :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 0 to 80\u00b0C continuous 80 to 100\u00b0C intermittent<\/span><\/p>\n<p><span style=\"font-size: 15px;\">Electrode Resistance :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 less than 50 M\u2126<\/span><\/p>\n<p><span style=\"font-size: 15px;\">Reproducibility :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00b12% <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Minimum Sample Size :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 300ml\/min\u00ad <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Size :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Electrode length \u00ad &#8211; 155mm <\/span><\/p>\n<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Body diameter\u00a0 \u00ad- 12mm <\/span><\/p>\n<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Cap Diameter \u00ad &#8211; 16mm <\/span><\/p>\n<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Cable Length \u00ad &#8211; 100cm<\/span><\/p>\n<p><span style=\"font-size: 15px;\">Calibration :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Manual using a test kit <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Short Term Storage :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Rinse the electrode thoroughly with DI water and place the tip <\/span><\/p>\n<p><span style=\"font-size: 15px;\">Long Term Storage :\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Rinse thoroughly with DI water and store dry. Replace the <\/span><\/p>\n<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 cap to protect the sensing element<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span style=\"font-size: 15px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Pi\u2019s <strong>FluoriSense<\/strong> range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.<\/span><\/p>\n<h4>Benefits<\/h4>\n<ul>\n<li><span style=\"font-size: 15px;\">Up to 2 years continuous operation<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Stable and reliable<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Excellent process control<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Integral temperature compensation<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Suitable for use in Autoflush<\/span><\/li>\n<li><span style=\"font-size: 15px;\">Help and consulting available<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":2216,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_cat":[111,307,516],"product_tag":[525,524,527,526,529,528,530],"_links":{"self":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product\/2263"}],"collection":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media\/2216"}],"wp:attachment":[{"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/media?parent=2263"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_cat?post=2263"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/siampollutek.co.th\/2018\/wp-json\/wp\/v2\/product_tag?post=2263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}