Features
- Excellent chemical compatibility
- High flow rates and low pressure drop
- Longer service life, reduce the total coasts
- Provide the hydrophilic membrane, without the prewetting processing, and save the replacement time
- Low extractables
- Manufactured in a clean room environment
- 100% integrity tested
Technical Specifications
Materials of Construction Recommended Operating Conditions
Filter Medium Expanded PTFE Maximum Operating Temperature 19 bar @82°C
(Polytetrafluorethylene)
Support and Drianage Polypropylene Fiber Maximum Different Pressure (forward) 50 bar @25°C
Core/Cage Polypropylene Maximum Different Pressure (Reverse) 3.4 bar @25°C
End Caps/Adaptor Polypropylene Recommended Replacement Pressure 2.4 bar
O-Ring/Gaskets Please refer to the ordering info.
Filter Dimensions
Outer Diameter 68.5 mm
Inner Diameter 33.0 mm
Filtration Area ≥0.74 m²
Flow Rate-Pressure Drop
Flow Rate-Pressure Drop of FluorPure G
FluorPure-G filters are specially optimized from the selection of membrane, which have high flow rate and velocity, can effectively delay filter blocking rate.
Flow Rate-Pressure Drop of FluorPure L
Applications
FluorPure G
- Ultra Pure chemical and gases
- Non-sterile venting
- Photoresists, Solvent, Electroplating solutions
- Chemical delivery system (CDS) filtration
FluorPure L
- Ultra Pure aqueous chemicals
- Chemical delivery and filling system filtration
- Eye drop and antibiotics
- Hot deionized water (less than 80°C)