Main Features
- 7 inch TFT screen and long life, more comfortable and sensitive silicone buttons. The instrument can show various scanning curves and charts for users to complete various tests without computers.
- Support USB storage and different data formats such as Excel, txt and photos(*.csv, *.qua,*.txt,*.bmp). Users can output test data to flash memory, open and edit them on computers directly without any auxiliary software.
- Advanced hardware and 32-bit Cortex_M3 processor with the clock speed 120MHz. The equipment can store 5000 pieces of data and 500 curves.
- High-efficiency holographic grating of 1200 lines/mm and ultra-low stray light.
- The equipment has Long-life socket type tungsten-halogen and deuterium lamps which can work up to 2000 hours, can switch the lamps according to test needs and record its working time automatically. Socket type lamps make the replacement much easier.
- Excellent silicon photodiode can guarantee the equipment is highly sensitive and stable.
- Huge sample chamber and various accessories can meet all kinds of needs.
- Can be connected to printer directly and output test charts and data.
- Powerful PC software.
- Strong extended capability: Standard 8GB memory can store huge test data and equipped with RS232, HOST USB port and standard USB interface.
UI Design
1. Photometry
Absorbency and transmittance test.
2. Quantitative test.
To test sample solution concentration, you can choose different methods like coefficient, standard curve, linearity, linear zero crossing and quadratic. Operators can choose single, double and tri-wavelength and change the coefficients of double and tri-wavelength. Advance arithmetic make curvilinear regression more precise and test data more accurate.
3. Kinetics Measurement (Time Scanning)
To test the sample chemical reaction process by fixed time scanning the sample solution with fixed wavelength. The equipment can calculate its changing rate after entering the corresponding parameters.
4. Wavelength Scanning (Qualitative Test)
To test sample solution absorbency peak, can scan the sample characteristic curve of any wavelength range between 190 and 1100nm. And do the chart overlay and arithmetic.
5. Multi wavelength testing
It is much more convenient for users to test the absorbency or do the arithmetic in case of several wavelengths for the same sample solution, which is much simpler than single wavelength testing.
6. DNA/Protein Measurement
It is a special function for specific users to make the operation easier.
Specifications
Model | C-7100 | C-7100S | C-7100A | C-7200 | C-7200S | C-7200PC | C-7200A |
Display | 7 inch TFT | No Screen | 7 inch TFT | ||||
Keyboard Control | Silicone Buttons | No Buttons | Silicone Buttons | ||||
Optical System | Single Beam | Double Beam | |||||
Holographic grating, 1200 lines/mm | |||||||
Slit Width | 2nm | 1nm | 0.5,1,2,4,5nm | 2nm | 1nm | 2nm, 1nm | 0.5,1,2,4,5nm |
Wavelength Range |
190 – 1100nm |
||||||
Wavelength Accuracy |
±0.3nm |
||||||
Wavelength Repeatability |
≤0.1nm |
||||||
Photometric Accuracy | 0.2%T(0-100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | ||||||
Photometric Repeatability | ≤0.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ||||||
Stray Light | ≤0.03%T@220nm,360nm | ||||||
Stability | ±0.001A/h@500nm | ||||||
Photometric Range |
0-200%T, -0.3-3.0A, 0-9999C(0-9999F) |
||||||
Baseline Flatness |
±0.0015A(200-1000nm) |
||||||
Noise | 0.0003A@500nm | ||||||
Working Mode | T,A,C,E | ||||||
Wavelength Setting | Automatic | ||||||
Scanning Speed | High, Medium and Low | ||||||
Detector | Solid Silicon Photodiode | ||||||
Light Source | Tungsten Halogen/Deuterium Lamp | ||||||
Data Output | RS232C Serial, USB Drive, USB HOST | ||||||
Processor | Cortex_M3, 120Mhz | ||||||
Power Requirements | AC 110-220V 50-60Hz | ||||||
Shipping Dimensions and Weight | 770*630*340mm, 27kg |