• You've just added this product to the cart:

    Anaerobic Control Analyzer

    0 out of 5

    Anaerobic Control Analyzer

    On-line monitoring of crical process parameters and process efficiency in anaerobic digesters

    Advanced features

    On-line, automatic measurements of volatile fatty acids (VFA), bicarbonate, alkalinity, pH and ammonia in one single run

    • Second generation design with less moving parts, simple maintenance and requiring no special analytical skills

    • Complete separation between electronics and wet part

    • Rapid results (10 – 15 min.) allow true process monitoring, protection and optimization

    • Dual range possibility for influent/effluent analysis

    • Multiplexing up to eight (8) sampling points possible

    • Incorporated industrial PC with AppliTek controller software

    • Extended data communication and exchange features

  • You've just added this product to the cart:

    IBU LYZER

    0 out of 5

    IBU LYZER

    The AppliTek IBULyzer® is an at-line beer analyzer developed by direct demand of the Belgian beer industry. The analyzer automates the manual isooctane extraction method for bitterness tests on a number of sampling points. A cost-effective analytical solution, IBULyzer® complements your internal quality control procedures allowing to brew each time that same unique beer, yet with tight control over the IBU/ EBU values.

     

  • You've just added this product to the cart:

    On-line Cyanide Analyzer

    0 out of 5

    On-line Cyanide Analyzer

    On-line, automati c monitoring of cyanide in surface water and industrial waste waters

    Advanced features

    • On-line, automatic colorimetric measurements

    • Minimalistic design: small footprint, less complexity

    • Complete separation between electronics and wet part

    • Smart features and add-on units reduce down-time and unnecessary checks substantially

    • Up to eight (8) sampling points possible

    • Incorporated industrial panel PC with AppliTek controller software

    • Extended data communication and exchange features

  • You've just added this product to the cart:

    On-line Microbiology Analyzer

    0 out of 5

    On-line Microbiology Analyzer

    Determina on of Bacterial and Pathogen Load Through Adenosine Triphosphate (ATP)

    The EZ-ATP® is capable of measuring the total ATP portions of any type of bacterial microorganism present in the water sample, such as fecal coliforms ( E . c o li ), sulphate reducing bacteria, nitrifying bacteria, Legionella… A high ATP value indicates a potential risk in surpassing a threshold value of microorganisms in the past or in the near future. The EZ-ATP® allows to differentiate between intracellular and extracellular ATP levels. This is important if one wants to conduct a true assessment of microbial activity and health :

    > Extracellular ATP also called free ATP, or the portion of ATP released by dead cells 

    > Total ATP, obtained after a proprietary, non-chemical lysis of the incoming sample 

    >  Intracellular ATP, obtained by calculation (total ATP minus extracellular), or the portion of ATP from the metabolically active living microorganisms

  • You've just added this product to the cart:

    On-line Total Nitrogen Analyzer

    0 out of 5

    On-line Total Nitrogen Analyzer

    On-line, automa c monitoring of Total Nitrogen (TN) in water and waste water

    Advanced features

    • On-line, automatic colorimetric measurements conform standard method 4500-N

    • Low temperature wet-chemical oxidation

    • Second generation design with small footprint, shorter liquid pathways and simple maintenance

    • Complete separation between electronics and wet part

    • Multiplexing up to eight (8) sampling points possible

    • Incorporated industrial PC with AppliTek controller software

    • Extended data communication and exchange features

  • You've just added this product to the cart:

    On-line Water Analyzer

    0 out of 5

    On-line Water Analyzer

    Compliance

                    The AppliCOD® Eco sets new standards in traditional wet chemistry methods by its advanced analytical mainframe, while compliance with internal industry methods is assured:

    Wet-chemical oxidation complying with standard method ISO 6060 by potassium dichromate

    Advanced features

    • True wet-chemical determination of Chemical Oxygen Demand (2 hour method with full sample oxidation)

    • Smart features and add-on units reduce down-time and unnecessary checks substantially

    • Superior performance and mechanical stability by using high quality components, tubing and programmable cleaning cycles

    • Up to three (3) sampling points possible

    • Incorporated industrial PC with AppliTek controller

  • You've just added this product to the cart:

    Series of On-line COD Analyzers

    0 out of 5

    Series of On-line COD Analyzers

    On-line, automa c monitoring of Chemical Oxygen Demand (COD) in water and waste water

    Advanced features

    • Compliance with international standard methods: wetchemical oxidation conform with ISO 6060 (potassium dichromate method); or ISO 8467 / JIS K0806 (potassium permanganate method)

    • Analytical mainframe available in several configurations depending on standard method, measuring ranges and individual requirements

    • MW model: accelerated sample oxidation by built-in microwave unit (dichromate method only)

    • Second generation design with small footprint and shorter liquid pathways

    • Complete separation between electronics and wet part

    • Multiplexing up to eight (8) sampling points possible

    • Incorporated industrial PC with AppliTek controller software

    • Extended data communication and exchange features

  • You've just added this product to the cart:

    Series of On-line Colorimetric Analyzers

    0 out of 5

    Series of On-line Colorimetric Analyzers

    Single-parameter water analysis for industrial and environmental applicaons

    Advanced features

    • On-line, automatic colorimetric measurements

    • Single methodology, single parameter, factory set measuring range

    • Standard measuring ranges with optional internal dilution for high to very high ranges

    • Minimalistic design: small footprint, less complexity

    • Complete separation between electronics and wet part

    • Smart features and add-on units reduce down-time and unnecessary checks substantially

    • Up to six (6) sampling points possible

    • Incorporated industrial panel PC with AppliTek controller software

    • Extended data communication and exchange features

  • You've just added this product to the cart:

    Series of On-line Titrimetric Analyzers

    0 out of 5

    Series of On-line Titrimetric Analyzers

    Flexibility in titra tion methodology

    Potentiometric or (photo) colorimetric titration ― the flexible analyzer mainframe of the TitriLyzer® Series of On-line Titrimetric Analyzers allows to carefully select the most suitable titration methodology in function of the application, parameter and measuring range.

    Advanced features

    • Straight-forward design, single methodology, single parameter, factory set measuring range

    • Complete separation between electronics and wet part

    • Smart features and add-on units reduce down-time and unnecessary checks substantially

    • Up to three (3) sampling points possible

    • Incorporated industrial PC with AppliTek controller software

  • You've just added this product to the cart:

    Series of On-line TOC Analyzers

    0 out of 5

    Series of On-line TOC Analyzers

    Cost-effecve monitoring of organic compounds in a wide array of water matrices

    Flexibility in configuraon

    The standard configuration of the AppliTOC® is based on the TOC methodology by hot-aerosol phase UV/persulfate. The analytical mainframe can also be configured to:

    • True Total Organic Carbon or

    • Total Inorganic Carbon or

    • Total Carbon

    Advanced features

    • Smart features and add-on units reduce down-time and unnecessary checks substantially

    • Built-in carbon removal system for purifying instrument air

    • Unique range-specific solid state IR detectors with automatic zero calibration

    • Up to three (3) sampling points possible

    • Incorporated industrial PC with AppliTek controller software